Convert_Eval_Product_2012StandardServer.bat script hangs

SecureAuth IdP Version affected: 9.0

Description:

The following script hangs and nothing happens when attempting to activate windows via batch script:

D:\MFCApp_Bin\Extras\2012Server\Convert_Eval_Product_2012StandardServer.bat 

Resolution: 

You will need to manually run the command.

Steps:

  1. Open up a Windows Command Prompt as Administrator.
  2. Enter the command:
    dism /online /set-edition:serverstandard /productkey:%prodkey% /accepteula
  3. Replace %prodkey% with the Windows Activation Key you have for the SecureAuth Appliance. Do not include the % characters. Include characters in the proper capitalized case and include dashes between them.
  4. Reboot the server. May take 10 minutes or more.